Rétrosignalisateur avec détecteurs d’occupation intégrés pour le bus s88
Ce décodeur vous offre aussi la possibilité d’étendre des systèmes s88 en existence par le nouveau standard s88-N: sur chaque module on peut choisir les câbles à utiliser
8-fold feedback module with integrated occupancy detectors for the s88-feedback bus. For s88 standard connections and s88-N.
-
It is suitable for the control of 8 track sections with a current load up to 3 Ampere. A short peak current up to 7 Ampere will be acceptable. Isolated rails or track sections to be monitored have to be simply connected to the output clamps of the feedback module to get a digital current supply. The track section can be isolated on one or on both sides.
-
The
8-fold feedback Module RM-GB-8-N with
integrated track occupancy report is separated into
two 4-fold occupancy devices. Therefore is it possible to
monitor tracks of two different booster circuits. The separation into two 4-fold track occupancy devices
simplifies as well the
monitoring of reverse-loops. More information about this issue can be found within the file
Reversing loop monitoring at the download section.
-
Including an integrated voltage monitor: If there is no voltage at the tracks (e.g. after short circuit) the occupied identification will be “frozen” during the interruption.
-
For the feedback module is no additional power supply required. This reduces the wiring effort.
-
The Feedback Module RM-GB-8-N is for s88-standard connections equipped with 6-poles pin bars and for bus connections according to s88-N with screened RJ-45 sockets.